Data Center and Facility 3 Phase UPS

3 Phase UPS power protection, solving today’s energy challenges while setting the standard for quality and innovation with fully integrated solutions for enterprise-wide networks, data centers, mission-critical systems, and industrial/manufacturing processes.


10kVA to 500kVA
The Symmetra PX is a world class, redundant, scalable, 3 Phase UPS power protection system designed to cost effectively provide high levels of availability. Seamlessly integrating into today's state-of-the-art data center designs, the Symmetra PX is a true modular system. Made up of dedicated and redundant modules--power, intelligence, battery and bypass, all engineered into a design that is easily and efficiently serviceable, this architecture can scale power and runtime as demand grows or as higher levels of availability are required. Symmetra PX serves as the core power train that drives InfraStruXure® systems for small and medium data centers but can also power individual "zones" of larger data centers. Highly manageable, the Symmetra PX features self-diagnostic capabilities and standardized modules which mitigate the risk of human error resulting in increased overall data center reliability.
400kVA to 1600kVA
Symmetra MW redefines high-power UPS technology as a modular, fault-tolerant UPS in the 400-1600 kilowatt range. Ideal for large data centers, complete buildings, healthcare and other critical facility protection requirements, the Symmetra MW can be scaled for rigorous and changing electrical demands. Symmetra MW provides increased availability through internal N+1 configurability, predictive failure notification and multi-module paralleling features. Setting a new standard for low cost of ownership, Symmetra MW delivers best-in-class efficiency and a reduction in rating of electrical infrastructure- wires, transformers and generators. Slide-in/out power modules, manageable external batteries and self-diagnosing features greatly reduce mean time to repair, and lithium-ion battery solutions reduce battery maintenance and cost. Symmetra MW provides a customizable system in a standardized design for any large on-demand network-critical physical infrastructure.
10kVA to 40kVA
Smart-UPS® VT offers centralized 3 Phase UPS power protection with the reliability of the award winning Smart-UPS family. Ideal for small data centers, large retail stores, regional offices, and dense power requirements, the Smart-UPS VT includes dual-mains input, automatic and maintenance bypasses, and scalable runtime with hot-swappable batteries for increased availability. The rack mounted version maximizes valuable floor space by incorporating UPS, power distribution, and additional battery capacity in a single rack. Low cost of ownership is achieved through best-in-class efficiency and a reduction in rating of electrical infrastructure - wires, transformers, and generators due the Smart-UPS VT's Soft Start feature.
10kVA to 40kVA
Galaxy 3500 UPS offers compact 3 Phase UPS power protection for commercial and technical facilities as well as industrial applications.The Galaxy 3500 includes dual-mains input, automatic and maintenance bypasses, and scalable runtime with hot-swappable batteries for increased availability. The parallel capability for redundancy and capacity, new optional bypass panels, and extended run battery frames provide increased flexibility. Low cost of ownership is achieved through best-in-class efficiency and a reduction in rating of electrical infrastructure - wires, transformers, and generators. The built in Network Management Card with temperature monitoring provides remote UPS power monitoring and management through a simple interface. Serviceability is greatly enhanced by user-replaceable batteries, front access servicing, and included start-up service for maximized configurabililty. All these features make the Galaxy 3500 the easiest UPS in its class to deploy, manage and maintain.
40kVA to 75kVA
Galaxy 4000 offers centralized 3 phase UPS power protection with the reliability of the Galaxy product family. Ideal for small to medium data centers, facilities and transportation, the Galaxy 4000 offers on-line double conversion technology for true isolation between input and output. Availability is achieved through zero transfer time for critical loads. The Network Management Card with temperature monitoring provides remote power management and monitoring through a simple Web/SNMP interface and provides integration with StruxureWare Data Center Expert. Serviceability is greatly enhanced by front panel access and includes start-up service for increased configurability. All these features make the Galaxy 4000 the easiest UPS in its class to install, manage and maintain.
160kVA to 225kVA(480V)160 to200kVA(400V)
Galaxy VM is a key component in the comprehensive Schneider Electric energy management solution for data center and industrial applications. Galaxy VM deploys state of the art technology to lower energy cost through very high efficiency ratings and the newly innovative ECOnversion mode. Galaxy VM seamlessly links to your electrical network using state of the art electrical performances like very wide input voltage range, high overload and short circuit capacity, and integrated back feed protection, providing excellent power quality. The highly compact Galaxy VM also links in with your facility monitoring systems and smart grid requirements and offers both traditional and modular energy storage flexibility that allows tailoring of the solution to specific needs. Galaxy VM features top and bottom cable entry without the need for an additional side cabinet, full front service access, back to the wall installation, and included start up service, making it one of the easiest UPSs in its class to deploy, install and maintain.
40kVA to130kVA
The Galaxy 5000 offers technology that increases performance and reliability. Online technology fully isolates and protects against all power quality disturbances. The upstream harmonics management allows a generator friendly installation and flexible configurations for even the most demanding designs. The Galaxy 5000 offers features such as paralleling capability for both capacity and redundancy, full front access, included start up for ease of serviceability, user friendly graphical display with multiple language options, and SNMP with network based power management options. All these features make the Galaxy 5000 one of the easiest UPS's in its class to manage and maintain.
300kVA to 500kVA
The EPS 7000 is the facility managers top choice UPS with its full front access design and all critical serviceable components reachable within minutes not hours. EPS 7000 product development was the largest joint effort with outside field and customer inputs but while still maintaining an aggressive footprint. These UPS modules allow IT and facilities managers to respond to increasing demands placed on power infrastructure in growing facilities by offering N+1 capabilities. EPS 7000 was the first in the industry to incorporate a 100% rated static switch on output of UPS inverter with no mechanical contactors which can age and weaken during UPS operation. Energy efficiency is a key feature for the EPS 7000 with a 93.5% system efficiency at full load and continues at high efficiency levels down to 25% load (93%). EPS 7000 provides pure flexibility, with auxiliary equipment such as: paralleling gear, external maintenance bypass, critical bus synchronization, bottom entry cabinets boxes, and distribution to meet specific site configuration while maximizing efficiency and output power quality.
555kVA to 1125kVA
The EPS 8000 is the primary choice 3 Phase UPS power supply in the large data center market with its benchmark on quality and availability, from 555 to1125kVA in a single box. Relying on advanced 12 pulse rectifier and inverter technologies to restrict total harmonic distortion to less than 5 percent. Copper galvanic isolation is provided for both input and output to UPS systems while isolating the DC ground from upstream devices in the event of a ground fault condition due to battery leakage. UPS systems deliver clean reliable power even in the harshest of electrical environments. Featuring 100% step-load capability which ensures a fast response to load changes with accurate voltage regulation. In addition, the EPS 8000 incorporates fault tolerant circuitry that protects UPS systems from accidental short circuits usually caused by load side failures or overloads. Core EPS is equipped with a 100 percent rated output static switch with a stable, reliable, predetermined response time. Low carbon footprint and full front access with zero electromechanical connections at the rear of the unit allows the unit to be installed against the wall.
10kVA to 80kVA
The Galaxy 300 3 Phase UPS provides trusted and reliable power supply protection for small data centers, commercial buildings and technical facilities. The on-line double conversion topology supplies true isolation between input and output with a zero transfer time. Up to 30 minutes of integrated battery backup, internal mechanical bypass and parallel capability allows for higher levels of availability. Remote and local monitoring/management capability is achieved through a simple Web/SNMP interface and a user friendly display available in 14 languages. Both three to three (3:3) and three to single (3:1) phase configurations are available for convenient power distribution. Serviceability is greatly enhanced by front panel access for ease of maintenance in confined spaces. All these features along with the included Start-Up and On-Site warranty service make the Galaxy 300 the easiest UPS in its class to install, manage and maintain.
Galaxy PW uninterruptible power supplies offer traditional 3 phase power protection for small to medium data centers, facilities and transportation, the Galaxy PW offers on-line double conversion technology for true isolation between input and output. Availability is achieved through zero transfer time for critical loads. Manageability is achieved with the Network Management Card that provides remote monitoring and management. Serviceability is greatly enhanced by front panel access and includes start-up and standard on-site warranty services. All of these features make the Galaxy PW the easiest of the uninterruptible power supplies in its class to manage and maintain.
225kVA to 500kVA
Galaxy 7000 provides secured power solutions for medium to large data centers, Industry, Buildings, Mission Critical and Shore Connection environments. The Galaxy 7000 is flexible/adaptable-its robust IGBT rectifier/inverter operates with any load (inductive, capacitive). This transformerless UPS maximizes system efficiency up to 94.5%, keeping operational costs low while providing the highest power quality to mission critical loads. Galaxy 7000 also offers ECO Mode, with up to 99% efficiency for single & parallel systems, and Efficiency Booster Mode for parallel installations. Galaxy 7000 includes features like N+1 parallel/redundant modules with several choices, including Isolated redundant, Integrated Parallel, & Centralized Static Switch, making the Galaxy 7000 a leader with high availability architectures for mission critical environments. Galaxy 7000 also includes the Smart Power Test feature (SPoT), which reduces overall system cost by removing the need for additional load banks. Galaxy 7000 is easy to install & maintain, with only front electrical connections & fully serviceable components. Galaxy 7000 includes additional UPS solutions, such as bus synchronization boxes; IP32 enclosures; back-feed protection; frequency conversion capabilities; flexible & extended battery solutions, including VRLA, NiCad, or Li-Ion; external matching maintenance bypass cabinets; and paralleling gear.
Galaxy VX Goes Global! 1000 kW Expandable, 1250 kW, 1500 kW N+1 (400V [IEC]) 500 kW, 625 kW, 750 kW, 1000 kW, 1250 kW, 1500 kW N+1 (480V [UL])
The Galaxy VX UPS is a highly efficient, scalable, flexible extension of the Schneider Electric Galaxy V-Series solutions for data center and industrial applications. Galaxy VX uses innovative features, including patented 4-level inverters and ECOnversion mode, to lower energy costs and meet changing business requirements. Galaxy VX provides N+1 redundancy at full capacity and delivers excellent power quality in demanding electrical environments, with a wide input voltage window, robust overload capacity, and power factor corrected input that eliminates oversizing of upstream gear. The Galaxy VX also links to facility monitoring systems such as the Schneider Electric StruxureWare for Data Center solution. Galaxy VX features a touch-screen display, top and bottom cable entry, full front service access, no rear clearance requirement, Smart Power Test (SPoT), and start-up service for efficient deployment. With support for traditional battery solutions as well as Lithium Ion and flywheel energy storage solutions, Galaxy VX provides the performance and flexibility required by today’s large data centers and mission critical applications.
10kVA to 100kVA Gutor PXC 3 Phase UPS is the first pre-engineered industrial UPS for light and heavy industrial environments, Highly compact, Gutor PXC works effortlessly with your facility monitoring systems and offers full industrial design options, and a wide temperature range from -10 to +55 °C. It also features top and bottom cable entry and with fully integrated isolation transformer option( 50 hz only). With full front service access, modular fans, and power modules, the Gutor PXC is one of the easiest UPS’s in its class to deploy, install and maintain.