AP8830 Features
Rack PDU 2G, Metered, ZeroU, 20A, 100-120V, (24) 5-20R
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Includes : Installation guide , Rack Mounting brackets , Safety guide , Serial configuration cable
Metered Rack PDU Features & Benefits
Availability
Flash Upgradeable |
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only) |
Remote Management Capabilities |
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. |
Local Current Monitoring Display |
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only) |
Alarm Thresholds |
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability) |
Load indicator LED |
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. |
Integrates with StruxureWare Data Center Expert |
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network |
Agility
Rack-Mountable |
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment. |
Wide range of input and output connections |
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip. |
Single input power source |
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections. |
Marketing Features
Load indicator LED |
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. |
Alarm Thresholds |
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. |
Local Current Monitoring Display |
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. |
Wide range of input and output connections |
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip. |
Local and web-based monitoring |
Status available to customers both in the data center and remotely |
Specs
Output
Nominal Output Voltage |
100V , 120V |
Overload Protection |
No |
Output Connections |
(24) NEMA 5-20R (Battery Backup) |
Input
Nominal Input Voltage |
100V , 120V |
Input frequency |
50/60 Hz |
Input Connections |
NEMA L5-20P |
Cord Length |
9.84ft ( 3meters ) |
Number of Power Cords |
1 |
Load Capacity |
1920VA |
Maximum Input Current |
20A |
Regulatory Derated Input Current (North America) |
40A |
Physical
Maximum Height |
70.5inches ( 1791mm , 179.1cm ) |
Maximum Width |
2.18inches ( 55mm , 5.5cm ) |
Maximum Depth |
1.72inches ( 44mm , 4.4cm ) |
Net Weight |
12.3lbs. ( 5.59kg ) |
Shipping weight |
16.28lbs. ( 7.4kg ) |
Shipping Height |
78.98inches ( 2006mm , 200.6cm ) |
Shipping Width |
6.48inches ( 164mm , 16.47cm ) |
Shipping Depth |
4.26inches ( 108mm , 10.83cm ) |
Color |
Black |
Environmental
Operating Environment |
23 - 113 °F ( -5 - 45 °C ) |
Operating Relative Humidity |
5 - 95 % |
Operating Elevation |
0-10000ft ( 0-3000meters ) |
Storage Temperature |
-25 - 65 °C |
Storage Relative Humidity |
5 - 95 % |
Storage Elevation |
0-50000ft ( 0-15000meters ) |
Conformance
Approvals |
cUL Listed, FCC Part 15 Class A, ICES-003, UL 60950-1, UL Listed |
Standard warranty |
2 years repair or replace |
Sustainable Offer Status
RoHS |
Compliant |
REACH |
REACH: Contains No SVHCs |
Battery Directive |
Compliant |
Battery Notes |
ts_Battery_Notes |