APC AP7899

Rack PDU, Metered, Zero U,14.4kW,208V,(24)C13,(4)C19,(2)L6-30R; 10' Cord

AP7899 Features

Rack PDU, Metered, Zero U,14.4kW,208V,(24)C13,(4)C19,(2)L6-30R; 10' Cord

Resettable circuit breakers Enables a quick recovery from overload events.
Toolless Rack Mounting Capabilities Server cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units in the rear of the enclosure.
Vertical Mounting Capabilities Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures.

Metered Rack PDU Features & Benefits

Availability

Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Integrates with StruxureWare Data Center Expert An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Load indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Remote Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Local Current Monitoring Display The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Agility

Rack-Mountable Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Wide range of input and output connections Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Marketing Features

Local Current Monitoring Display The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
Local and web-based monitoring Status available to customers both in the data center and remotely
Wide range of input and output connections Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Load indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Specs

Output

Nominal Output Voltage 208V
Overload Protection Yes
Maximum Total Current Draw 24
Output Connections (24) IEC 320 C13 (Battery Backup)
(4) IEC 320 C19 (Battery Backup)
(2) NEMA L6-30R (Battery Backup)

Input

Nominal Input Voltage 208V 3PH
Input frequency 50/60 Hz
Input Connections CS8365
Cord Length 10ft ( 3.05meters )
Number of Power Cords 1
Load Capacity 14400VA
Maximum Input Current 50A
Regulatory Derated Input Current (North America) 40A

Physical

Maximum Height 70.0inches ( 1778mm , 177.8cm )
Maximum Width 2.2inches ( 56mm , 5.6cm )
Maximum Depth 3.75inches ( 95mm , 9.5cm )
Net Weight 22.8lbs. ( 10.36kg )
Shipping weight 31.5lbs. ( 14.32kg )
Shipping Height 81.0inches ( 2057mm , 205.7cm )
Shipping Width 12.25inches ( 311mm , 31.1cm )
Shipping Depth 3.12inches ( 79mm , 7.9cm )
Color Black

Environmental

Operating Environment 23 - 113 °F ( -5 - 45 °C )
Operating Relative Humidity 5 - 95 %
Operating Elevation 0-10000ft ( 0-3000meters )
Storage Temperature -25 - 65 °C
Storage Relative Humidity 5 - 95 %
Storage Elevation 0-50000ft ( 0-15000meters )

Conformance

Approvals cUL Listed, CSA, FCC Part 15 Class A, ICES-003, PSE, UL 60950, UL Listed
Standard warranty 2 years repair or replace

Sustainable Offer Status

RoHS Compliant
REACH REACH: Contains No SVHCs
PEP Available in Documentation tab
EOLI Available in Documentation tab
Battery Directive Compliant
Battery Notes ts_Battery_Notes